INPUT SIGNALS
Analog Input:Resistance — PT100
Voltage—0~5V, 1~5V or mV
Current—0~10mA, 4~20mA or 0~20mA
Thermocouple— K,E
Pulse Input: Wave—Rectangular, sine or triangle wave
Amplitude—More than 4V(or specified by user)
Range—0~5KHz
Switch Input: Start, stop or reset
Amplitude—Input isolated by Photoelectric Generator >4V
OUTPUT SIGNALS
Analog Input:0~10mA, 4~20mA, 0~5V, 1~5V
Switch Input:Relay controlling output(AC220V/3A, .DC24V/5A, .resistance load)
SCR(silicon controlled) output 400V/0.5A
SSR(solid relay) output 6~9V/50mA
Feed output: DC24V/30mA
Communication:bi-wiring, trio-wiring or quad-wiring systems,baud rate is changeable
PRECISION
Display precision for measuring:0.2%FS±1 digit or .5%FS±1 digit
Transforming precision for frequency:±1 pulse (LMS), better than 0.2%
DISPLAY METHOD
0~9999 display instant flow measured value
0~9999999999 display accumulated flow value
1999~9999 display measured value of temperature compensation
1999~9999 display measured value of pressure compensation
1999~9999 display measured flow, pressure or frequencyvalue, display date and time
Display LED working state (high-light LED display or LED display with backlight)
CONTROLLING METHOD ON/OFF with back-difference
PRINT CONTROLLING Directly connect with various types of serial micro-printer. Communicating method is RS-232.
PRINT PRECISION The same as the measuring precision of instrument.
ALARMING METHOD
Can select the alarm output of relay high and low limit with LED indicating alarm..
QUANTITATIVE CONTROLLING METHOD
Can select relay controlling with LED indicating output when the getting the set flow value. Can select relay controlling quantitative flow process with LED indicating output.
ALARM PRECISION ±1 digit
COMMUNICATING METHOD
Bi-directional serial communicating, such as RS-232, RS-422, RS-485 and so on.
The baud rate(300~9600bps) can be arbitrarily set by setting internal parameter.
The system adopts principal and subordinate communicating method as to realize communicating of multi SF instruments with microcomputers
SETTING METHOD
Faceplate key touching setting digits. Keep set values permanently if power is broken. Lock set parameters by password.
PROTECTTING METHOD
Auto reset by programming if the voltage is too low. Auto reset by programming if the operation is abnormal(Watch Dog). Since power is broken keep the accumulated flow value for more than two years and keep set parameters permanently.
USING ENVIRONMENT
Ambient temperature: 0~50℃
Relative humidity: ≤85%RH
Power supply: .AC 220V+10-15% (50Hz±2Hz)
AC 90~260V——switch power
DC 24V±2V——switch power
Get rid of strong corrosive gas
WEIGHT . 500 g ( AC 220V power supply )
. 300 g ( Switching power supply ) |