| LBYN serials scrape-board flowmeter (Also called Rotary Vane Flowmeter)is a newly-type,paricular-designed,precisely process and assembling positive displacement flowmeter.It has only one rotator,circling with uniform velocity.With feature of precise measurement,smooth running,low nosie,,long service lifetime. It is widely used to measure liquid from low vicosity to extreme high viscosity.The Patent No.: ZL 02 2 15726.3 | |
 |
|
1.High accuracy to 0.1% 2.Smooth running and low noise and vibration 3.Long service lifetime 4.Can Match with photoelectric converter to signal output
5.Double Cases
6. Low Pressure Drop |
|
|
 | |
 |
| As the under picture shows: It has quantificational chamber in the flowmeter body. when the liquid full of the chamber, it will push the rotator rotating by the pressure of the liquid. Counting the rotating will get the flow of the liquid. |
|
| |
 |
|
|
 |
Accuracy and Basic Error
|
Accuracy |
0.1% |
0.2% |
0.5% |
|
The Basic error of the flow |
?.1% |
?.2% |
?.5% |
| Repeatability: |
0.03% |
| Nominal Diameter(DN): |
1.6,2.5,4.0,6.4MPa; |
| Working Temp.: |
-30?~+80?,-30?~+120?,+100?-+200? |
| Ambient Temp.: |
-30?~+60?; |
| Connect Flange: |
1.6Mpa-6.6MPa(Manufacturer Standard or Other Standard Can Customer made) |
| Photoelectric Converter: |
ExdIIBT4 Anti-explosion certificate No.:2012047; ExdIICT4 Anti-explosion certificate No.:GYB03478; |
| Power Supply: |
12~24VDC?Frequency Of Pulse Output:<10000Hz?Max. Voltage Of Pulse:12V |
Character Curve |
|
 | |
 |
 |
1.Pipe Connection See Left Picture a. The installing position should select without large vibration, extrem temperature and high magnetic field interfere. And the position is also easy installing and maintenance. b. When installing flowmeter to a new pipe, the pipe should be cleared thoroughly before install flowmeter to pipe. c. The flowmeter can be installed at any angle. There should leave enough space for maintenance.The picture is a sample of installation. d. Please notice that the flow direction should same as the arrow on the flowmeter body. e. A filter or strainer should install before the flowmeter avoid flowmeter blocked by impurity. When gas content in the measured liquid, A gas eliminitor recommend to install before flowmeter. A gas eliminitor can expell the gas in the liquid to better the accuracy. f. The flow adjusting valve should install down stream of the flowmeter. g. When the meterhead can not easily to be read, the user can remove the bolt of the flowmeter and circled the meterhead to the easily read direction. h. For the material of cast steel steel flowmeter, there should avoid water flow in the flowmeter. The water may cause the rotator rust and block.
2. Wiring When need signal output, please wire and install according to the manual of the LPJ Photoelectric Pulse/Current Generator. | |
 |
|
Accuracy:0.5%,0.2%
|
DN
(mm) |
Flow Range (m3/h) |
litre/Pulse |
|
0.3~0.8 mPa.s |
0.8~2 mPa.s |
2~5 mPa.s |
8~400 mPa.s |
400~2000 mPa.s |
2000~5000 mPa.s |
|
0.5% |
0.2% |
0.5% |
0.2% |
0.5% |
0.2% |
0.5% |
0.2% |
0.5% |
0.2% |
0.5% |
0.2% |
|
25 |
3~10 |
|
2.8~10 |
|
1.6~10 |
|
1.2~10 |
|
0.5~6.4 |
|
0.5~4 |
|
0.01 |
|
40 |
3~12 |
|
2.8~14 |
|
1.6~16 |
|
1.2~14 |
|
0.5~6.4 |
|
0.5~4 |
|
|
50 |
7~28 |
9~28 |
6.5~31.5 |
8~31.5 |
3.5~35 |
7~35 |
3~31.5 |
6~31.5 |
2~20 |
2.8~15 |
1.2~12 |
2~10 |
|
80 |
14~56 |
18~56 |
13~63 |
16~64 |
7~70 |
14~70 |
6~60 |
12~60 |
4~40 |
6~30 |
2.5~25 |
4~18 |
0.1 |
|
100 |
20~80 |
25~80 |
18~90 |
23~90 |
10~100 |
20~100 |
9~90 |
18~90 |
5~50 |
9~45 |
3.5~35 |
6~30 |
|
150 |
54~216 |
70~210 |
48~240 |
60~240 |
27~270 |
54~270 |
24~240 |
48~240 |
12~120 |
22~110 |
9~90 |
16~80 |
|
200 |
80~320 |
106~320 |
72~360 |
90~360 |
40~400 |
80~400 |
36~360 |
70~360 |
18~180 |
36~180 |
15~150 |
24~120 |
|
250 |
120~480 |
160~480 |
108~540 |
135~540 |
60~600 |
120~600 |
54~540 |
110~540 |
24~240 |
50~240 |
20~200 |
36~180 |
|
300 |
200~800 |
260~800 |
180~900 |
225~900 |
100~1000 |
200~1000 |
90~900 |
180~900 |
40~400 |
80~400 |
35~350 |
60~300 |
|
400 |
400 ~1600 |
540 ~1600 |
360 ~1800 |
450 ~1800 |
200 ~2000 |
400 ~2000 |
180 ~1800 |
360 ~1800 |
80 ~800 |
160 ~800 |
60 ~600 |
120 ~600 |
1 | |
Accuracy:0.1%
|
DN
(mm) |
Flow Range (m3/h)
|
Litre/Pulse |
|
0.8~2mPa.s |
2~5mPa.s |
5~100mPa.s |
100~400mPa.s |
400~2000mPa.s |
2000~5000mPa.s |
|
50 |
9~21 |
9~28 |
9~28 |
7.5~24 |
5~15 |
3.5~10 |
0.01 |
|
80 |
18~42 |
18~54 |
18~54 |
18~48 |
10~28 |
7~18 |
0.1 |
|
100 |
25~60 |
25~80 |
25~80 |
20~70 |
15~45 |
10~30 |
|
150 |
70~180 |
70~220 |
70~220 |
55~200 |
40~108 |
25~80 |
|
200 |
106~280 |
100~320 |
100~320 |
80~280 |
60~180 |
40~120 |
|
250 |
160~420 |
150~480 |
150~480 |
120~420 |
90~240 |
60~180 |
|
300 |
260~700 |
250~800 |
250~800 |
200~700 |
150~400 |
100~300 |
|
400 |
540~1400 |
500~1600 |
500~1600 |
400~1400 |
300~800 |
200~600 |
1 |
|
 |
|
|
|
DN(mm) |
Nominal Pressure(MPa) |
A |
B |
C |
D |
E |
K |
N |
F |
Weight(kg) |
|
25 40 |
1.6, 2.5, 4.0 |
300 |
110 |
260 |
220 |
35 |
|
|
|
30 |
|
6.4 |
|
32 |
|
50 |
1.6, 2.5, 4.0 |
360 |
192 |
522 |
316 |
89 |
216 |
3 |
15 |
82 |
|
6.4 |
326 |
105 |
|
80 |
1.6?2.5?4.0? |
460 |
240 |
650 |
400 |
118 |
260 |
3 |
15 |
128 |
|
6.4 |
450 |
160 |
|
100 |
1.6?2.5?4.0? |
500 |
266 |
677 |
440 |
140 |
343 |
3 |
15 |
185 |
|
6.4 |
470 |
231 |
|
150 |
1.6?2.5?4.0? |
650 |
330 |
809 |
550 |
165 |
390 |
3 |
20 |
280 |
|
6.4 |
584 |
350 |
|
200 |
1.6?2.5?4.0? |
700 |
411 |
980 |
644 |
229 |
432 |
4 |
24 |
838 |
|
6.4 |
680 |
1090 |
|
250 |
1.6?2.5?4.0? |
1000 |
559 |
1208 |
758 |
279 |
533 |
4 |
32 |
1325 |
|
6.4 |
810 |
1660 |
|
300 |
1.6?2.5?4.0? |
1000 |
660 |
1387 |
880 |
381 |
686 |
6 |
32 |
2230 |
|
6.4 |
900 |
2900 |
|
400 |
1.6?2.5?4.0? |
1168 |
775 |
1671 |
1118 |
457 |
838 |
6 |
32 |
3100 |
|
6.4 |
3600 | | |
 |
|
Basic
Type |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Illuminate |
|
|
DN |
Nominal
Pressure |
Working
Temperature |
Signal Position |
Meter head |
Character |
Signal |
Accuracy |
|
LBYN |
- |
|
|
|
|
|
|
|
|
Means: Scrape Board Flowmeter |
|
0 |
|
|
|
|
|
|
|
Nominal Diameter:25mm |
|
1 |
|
|
|
|
|
|
|
Nominal Diameter:40mm |
|
2 |
|
|
|
|
|
|
|
Nominal Diameter:50mm |
|
3 |
|
|
|
|
|
|
|
Nominal Diameter:80mm |
|
4 |
|
|
|
|
|
|
|
Nominal Diameter:100mm |
|
5 |
|
|
|
|
|
|
|
Nominal Diameter:150mm |
|
6 |
|
|
|
|
|
|
|
Nominal Diameter:200mm |
|
7 |
|
|
|
|
|
|
|
Nominal Diameter:250mm |
|
8 |
|
|
|
|
|
|
|
Nominal Diameter:300mm |
|
9 |
|
|
|
|
|
|
|
Nominal Diameter:400mm |
|
|
1 |
|
|
|
|
|
|
Nominal Pressure:1.6MPa |
|
|
2 |
|
|
|
|
|
|
Nominal Pressure:2.5MPa |
|
|
3 |
|
|
|
|
|
|
Nominal Pressure:4.0MPa |
|
|
4 |
|
|
|
|
|
|
Nominal Pressure:6.4MPa |
|
|
|
1 |
|
|
|
|
|
Working Temperature:-10?~80? |
|
|
|
2 |
|
|
|
|
|
Working Temperature:--10?~+120? |
|
|
|
|
0 |
|
|
|
|
No Signal Output |
|
|
|
|
1 |
|
|
|
|
Meter Head Side Signal Output |
|
|
|
|
2 |
|
|
|
|
Meter Head Under Signal Output |
|
|
|
|
|
M1 |
|
|
|
Mechanical Pointer Meter Head |
|
|
|
|
|
M2 |
|
|
|
Mechanical Meter Head With Zero Reset |
|
|
|
|
|
M3 |
|
|
|
Large Numerical Mechanical Meter Head With Zero Reset |
|
|
|
|
|
M4 |
|
|
|
Import Large Numerical Mechanical Meter Head With Zero Reset |
|
|
|
|
|
D |
|
|
|
Electric Meter Head |
|
|
|
|
|
|
P |
|
|
Standard |
|
|
|
|
|
|
Q |
|
|
Special for gasoline and LPG |
|
|
|
|
|
|
|
F |
|
Photoelectric Converter:Standard Pulse Output |
| |
|
|
|
|
|
I |
|
Photoelectric Converter:4-20mA |
| |
|
|
|
|
|
|
|
F1 |
|
Electric Meter Head:Standard Pulse Output |
| |
|
|
|
|
|
I1 |
|
Electric Meter Head: |
| |
|
|
|
|
|
|
0.5 |
Accuracy:0.5% |
| |
|
|
|
|
|
|
0.2 |
Accuracy:0.2% |
| |
|
|
|
|
|
|
0.1 |
Accuracy:0.1% |
Example:LBYN-5312M3PI0.2 Note: Model LBYN Scrape Board Flowmeter?DN:150mm?Nominal Pressure:4.0Mpa?Fluid Temp.:-10?~+80??Side Signal Output,Large Numerical Mechanical Meter Head With Zero Reset,Photoelecric 4-20mA Output(Anti-explosion Grade:Exd?BT4),Accurqacy:0.2%
F,I:means photoelectric converter signal output,Anti-explosion Grade:Exd?BT4; F1,I1:electric meter head with signal output,Anti-explosion Grade:Exd?CT4 | |
 |
Flowmeter Model:_________________; 1,Nominal Diameter:_________________mm; 2,Fluid Pressure:Max.:_____ Normal_____ Min._____Mpa; 3,Fluid Temperature:___________? 4,Signal Output Position: 5,Meter Head Type: 6,Character:Standard or Gasoline or LPG; 7,Need Signal Output:______________________; 8,Accuracy:?0.5% ?0.2% ?0.1%; 9,Fluid Name:______________________; 10,Fluid Density:____________________; 11,Fluid Viscosity_____________mpa.s At___________? 12,Flow Range:Max.:_____ Normal_____ Min._____m3/h; 13,Flange Standard:____________________; 14,Filter Model :__________?
|
|
Company: |
Shanghai Yinuo Instrument Co., Ltd. |
|
Address: |
No.7508 North Jiasong Road, Huangdu Town, Jiading District, Shanghai |
|
Postcode: |
201804 |
|
Tel: |
0086-21-3953 1213 |
|
Fax: |
0086-21-3953 1508 |
|
Website: |
http://www.yinuochina.com |
|
E-Mail: |
shynyb@yahoo.com.cn 59598312@163.com |
|
Mobile Phone: |
0086-137 8890 0279 |
|
Contacter: |
Steven Shao (Vice General Manager) ??? | |
| | |